Electrical Propertics
|
|
|
|
1.DC Resistance of Individual Conductor(20℃)
|
|
Nominal Conductor Diameter(mm)
|
0.4
|
0.5
|
0.6
|
0.8
|
|
|
DC Resistance (Ω/km)
max
|
148.0
|
95.0
|
65.8
|
36.6
|
|
|
|
|
|
2.DC Resistance Unbalance
|
|
Nominal Conductor Diameter(mm)
|
0.4
|
0.5
|
0.6
|
0.8
|
|
|
DC Resistance Average Value≤
|
1.5
|
1.5
|
1.5
|
1.5
|
|
|
Unbalance%
Max Value≤
|
5.0
|
5.0
|
5.0
|
4.0
|
|
|
|
|
|
3.Insulation Resistance Between Conductor and Earth or Shield
|
|
(20℃.DC100-500V)≥1000MΩ.km
|
|
|
|
4.Electric Strength or Insulation(DC)
|
|
Between Conductors: 1000V 1min Undisruptive
|
|
Between Conductor and Shield: 3000V 1min Undisruptive
|
|
|
|
5.Capacitance(nF/km)
|
|
Cables Over 10pairs
|
|
Average Value: 52+/-2.0
|
|
Max Value: 57.0
|
|
|
|
6.Capacitance Unbalance, 0.8KHz or 1KHz pF/km
|
|
Pair to Pair: max 250(200)
250(200)
|
|
Pair to Earth: max 2630 2630
|
|
Average Value: ≯570(490)
|
|
|
|
7.Remote-End Crosstalk Defence(150KHz)
|
|
Basic Unit or 30pairs Average Power Value ≥69dB/km
|
|
Subunit: 12pairs and 13pairs and 10pairs and 20pairs
|
|
Average Power Value ≥68dB/km
|
|
|
|
8.Near-End Crosstalk Attenuation:
|
|
10pairs Composed(m-s) ≥53dB
|
|
12pairs and 13pairs Composed(m-s) ≥54dB
|
|
20pairs and 30pairs or Basic Unit Composed(m-s) ≥58dB
|
|
Adjacent Basic Subunit Composed(m-s) ≥63dB
|
|
Adjacent Basic Unit Composed(m-s) ≥64dB
|
|
Two Relative Basic Unit or Subunit Composed in Unit (m-s) ≥70dB
|
|
Basic Unit or Subunit Composed in Different Unit(m-s) ≥79dB
|
|
|
|
9.Natural Attenuation: (20℃)
|
|
Nominal Conductor Diameter(mm)
|
0.4
|
0.5
|
0.6
|
0.8
|
|
|
Average Value≤150KHz
|
12.1
|
9.0
|
7.2
|
5.7
|
|
|
Value≤1024KHz
|
27.3
|
22.5
|
18.5
|
13.7
|
|
|